| Anonymous | Login | Signup for a new account | 08-09-10 23:38 EST |
| Main | My View | View Issues | Change Log | Docs |
| Viewing Issue Advanced Details [ Jump to Notes ] | [ Issue History ] [ Print ] | ||||||||
| ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||||
| 0000038 | [Software] Connection | minor | have not tried | 18-08-07 13:58 | 20-08-07 20:31 | ||||
| Reporter | Peter | View Status | public | ||||||
| Assigned To | Peter | ||||||||
| Priority | normal | Resolution | fixed | Platform | |||||
| Status | closed | OS | |||||||
| Projection | none | OS Version | |||||||
| ETA | none | Fixed in Version | 1.3.3 | Product Version | 1.3.3 | ||||
| Product Build | beta3 | ||||||||
| Summary | 0000038: check for port open when reconnecting when gauges showing | ||||||||
| Description | the current auto reconnect may not work for any pda's that close ports on turning pda off maybe? at the moment the reconnect doesnt check for whether the port is still open. | ||||||||
| Steps To Reproduce | |||||||||
| Additional Information | |||||||||
| Attached Files | |||||||||
|
|
|||||||||
Notes |
|
|
(0000021) Peter 20-08-07 20:31 |
it now closes and reopens com port each time it attempts reinitialisation (hopefully this wont cause issues for anyone else) |
| Mantis 1.0.8[^]
Copyright © 2000 - 2007 Mantis Group
36 total queries executed. 30 unique queries executed. |